EXO2 Multiparameter Sonde
EXO2 Multiparameter Sonde
7-Port Multiparameter Water Quality Sonde
Anti Fouling | Central Wiper |
---|---|
Depth / Pressure Rating / Limit | 0 to 250 m (0 to 820 ft) |
Desktop Software Compatible | Yes |
Flow Cell | Yes |
Languages | English, German, Japanese, Chinese, French, Spanish |
Logging Capabilities | Yes |
Medium | Fresh, sea or polluted water |
Memory | 512 MB total memory, >1,000,000 logged readings |
Monitoring | Yes |
Multiparameter | Yes |
Operating Temperature | -5 to +50°C |
Power | 4 Alkaline Batteries |
Sampling | Yes |
Smart Sensors / Ports | Yes |
Storage Temperature | -20 to +80°C |
Unit of Measure | Parameter Dependent |
User Calibratable | Yes |
Waterproof | Yes |
EXO2 Specifications | ||
---|---|---|
Battery Life | 90 days* | |
Communications | Computer Interface: Bluetooth wireless technology (between sonde and handheld or computer with KOR software), USB Output Options: USB with signal output adapter (SOA); RS-232 & SDI-12 with DCP-SOA. |
|
Diameter | 7.62 cm (3.00 in) | |
Length | 71.10 cm (28.00 in) | |
Peripheral Ports | 1 power communication port; 1 auxiliary port for third-party sensors (future functionality; not active yet) | |
Sample Rate | Up to 4 Hz | |
Sensor Ports | 7 (6 ports available when central wiper used) | |
Warranty: 3 mos | Replaceable reagent modules for ammonium, chloride, and nitrate | |
Warranty: 1 yr | Optical DO membranes and replaceable reagent modules for pH and pH/ORP | |
Warranty: 2 yrs | Cables; sonde bulkheads; handheld; conductivity, temperature, depth, and optical sensors; electronics base for pH, pH/ORP, ammonium, chloride, and nitrate sensors; and accessories | |
Weight | 3.60 kg (7.90 lbs) |
*Typically 90 days at 20˚C at 15-minute logging interval; temperature/conductivity, pH/ORP, DO, total algae, and turbidity sensors installed with central wiper that rotates once per logging interval on EXO2. Battery life is heavily dependent on sensor configuration.
EXO Parameter Measured | Sensor** | Range | Accuracy | Response | Resolution |
---|---|---|---|---|---|
Ammonium (freshwater only) |
Ammonium Sensor Ammonia with pH sensor SKU: 599710 |
0 to 200 mg/L (0 to 30˚C) | ±10% of reading or 2 mg/L-N, w.i.g. | T63<30 sec | 0.01 mg/L |
Barometric Pressure | Integral Barometer | 375 to 825 mmHg | ±1.5 mmHg from 0 to 50°C | - | 0.1 mmHg |
Blue-green Algae, Phycocyanin |
Total Algae Sensor
SKU: 599102-01
|
0 to 100 μg/L; 0 to 100 RFU; |
Linearity: R2 >0.999 for serial dilution of Rhodamine WT solution from 0 to 100 μg/mL BGA-PC equivalents | T63<2 sec | 0.01 μg/L; 0.01 RFU |
Blue-green Algae, Phycoerythrin |
Total Algae Sensor
SKU: 599103-01
|
0 to 280 μg/L; 0 to 100 RFU; |
Linearity: R2 >0.999 for serial dilution of Rhodamine WT solution from 0 to 280 μg/mL BGA-PE equivalents | T63<2 sec | 0.01 μg/L; 0.01 RFU |
Chloride (freshwater only) |
Chloride Sensor SKU: 599711 |
0 to 18000 mg/L-Cl (0 to 30˚C) | ±15% of reading or 5 mg/L-Cl, w.i.g. | T63<30 sec | 0.01 mg/L |
Chlorophyll | Total Algae Sensor | 0 to 400 μg/L Chl; 0 to 100 RFU |
Linearity: R2 >0.999 for serial dilution of Rhodamine WT solution from 0 to 400 μg/L Chl a equivalents | T63<2 sec | 0.01 μg/L Chl; 0.01 RFU |
Conductivity1 | Conductivity / Temperature Sensor SKU: 599870 |
0 to 200 mS/cm | 0 to 100: ±0.5% of reading or 0.001 mS/cm, w.i.g.; 100 to 200: ±1% of reading |
T63<2 sec | 0.0001 to 0.01 mS/cm (range dependent) |
Depth - 10 m | Integral, Non-vented Depth Sensor3 | 0 to 10 m (0 to 33 ft) |
±0.04% FS (±0.004 m or ±0.013 ft) | T63<2 sec | 0.001 m (0.001 ft) (auto-ranging) |
Depth - 100 m | Integral, Non-vented Depth Sensor3 | 0 to 100 m (0 to 328 ft) |
±0.04% FS (±0.04 m or ±0.13 ft) | T63<2 sec | 0.001 m (0.001 ft) (auto-ranging) |
Depth - 250 m | Integral, Non-vented Depth Sensor3 | 0 to 250 m (0 to 820 ft) |
±0.04% FS (±0.10 m or ±0.33 ft) | T63<2 sec | 0.001 m (0.001 ft) (auto-ranging) |
Dissolved Oxygen, % air saturation | Optical Dissolved Oxygen Sensor SKU: 599100-01 |
0 to 500% air saturation |
0 to 200%: ±1% of reading or 1% saturation, w.i.g.; 200 to 500%: ±5% of reading 4 |
T63<5 sec5 | 0.1% air saturation |
Dissolved Oxygen, mg/L | Optical Dissolved Oxygen Sensor SKU: 599100-01 |
0 to 50 mg/L | 0 to 20 mg/L: ±0.1 mg/L or 1% of reading, w.i.g.; 20 to 50 mg/L: ±5% of reading 4 |
T63<5 sec5 | 0.01 mg/L |
fDOM (CDOM) |
fDOM Sensor SKU: 599104-01 |
0 to 300 ppb Quinine Sulfate equivalents (QSU) | Linearity: R2 > 0.999 for serial dilution of 300 ppb QS solution Detection Limit: 0.07 ppb QSU |
T63<2 sec | 0.01 ppb QSU |
Level, Vented - 10 m | Integral Vented Level Sensor | 0 to 10 m (0 to 33 ft) | ±0.03% FS (±0.003 m or ±0.010 ft) | T63<2 sec | 0.001 m (0.001 ft) |
Nitrate (freshwater only) |
Nitrate Sensor SKU: 599709 |
0 to 200 mg/L-N (0 to 30˚C) | ±10% of reading or 2 mg/L-N, w.i.g. | T63<30 sec | 0.01 mg/L |
pH | pH Sensor SKU:599701 guarded, 599702 unguarded pH/ORP Sensor SKU:599705 guarded, 599706 unguarded |
0 to 14 units | ±0.1 pH units within ±10˚C of calibration temp; ±0.2 pH units for entire temp range7 |
T63<3 sec8 | 0.01 units |
ORP | pH/ORP Sensor SKU:599705 guarded, 599706 unguarded |
-999 to 999 mV | ±20 mV in Redox standard solution | T63<5 sec6 | 0.1 mV |
Temperature | Conductivity / Temperature Sensor SKU: 599870 |
-5 to 35°C 35 to 50°C |
±0.01°C2 ±0.05°C2 |
T63<1 sec | 0.001 °C |
Turbidity9 | Turbidity Sensor SKU: 599101-01 |
0 to 4000 FNU | 0 to 999 FNU: 0.3 FNU or ±2% of reading, w.i.g.; 1000 to 4000 FNU: ±5% of reading10 |
T63<2 sec | 0 to 999 FNU = 0.01 FNU; 1000 to 4000 FNU = 0.1 FNU |
Salinity | Calculated from Conductivity and Temperature11 | 0 to 70 ppt | ±1.0% of reading or 0.1 ppt, w.i.g. | T63<2 sec | 0.01 ppt |
Specific Conductance | Calculated from Conductivity and Temperature11 | 0 to 200 mS/cm | ±0.5% of reading or .001 mS/cm, w.i.g. | - | 0.001, 0.01, 0.1 mS/cm (auto-scaling) |
Total Dissolved Solids (TDS) | Calculated from Conductivity and Temperature11 | 0 to 100,000 mg/L Cal constant range 0.30 to 1.00 (0.64 default) |
Not Specified | - | Variable |
Total Suspended Solids (TSS) | Calculated from Turbidity and user reference samples | 0 to 1500 mg/L | Not specified | T63<2 sec | Variable |
**Specifications indicate typical performance and are subject to change. All sensors have a depth rating to 250 m (820 ft), except shallow and medium depth sensors, ammonium, chloride, and nitrate. Accuracy specification is attained immediately following calibration under controlled and stable environmental conditions. Performance in the natural environment may vary from quoted specification.
w.i.g. = whichever is greater
EXO sensors are not compatible with YSI 6-Series sondes, sensors, or handheld.
Ordering Code!